Technical Glossary

Solar Fault Codes &
Industry Terms

A complete reference for solar professionals — plain-language definitions for inverter fault codes, industry acronyms, and technical terms.

71 terms
A

AC

Acronym

Alternating Current. The form of electricity delivered by the utility grid and consumed by most loads. Solar inverters convert DC from the panels into AC for use in the building or export to the grid.

AFCI

Acronym

Arc Fault Circuit Interrupter. A safety device required by NEC 690.11 for PV systems on or penetrating buildings. Detects arc faults in DC wiring and disconnects power before a fire can ignite.

Anti-Islanding

Technical Term

Inverter functionality required by IEEE 1547 that detects when the grid is down and disconnects the inverter to prevent energizing the grid during a utility outage, protecting line workers.

Arc Fault

Fault Code

An unintended electrical discharge between conductors or between a conductor and ground. Arc faults in PV systems can cause fires and are detected by AFCI devices. Common inverter error: 'Arc Fault Detected' or 'AFCI Trip'.

B

BESS

Acronym

Battery Energy Storage System. A system that stores electrical energy in batteries for later use. Can provide backup power, peak shaving, demand charge reduction, or grid services. Common BESS brands: Tesla Powerwall/Megapack, Enphase IQ Battery, LG RESU, SolarEdge.

Bifacial Module

Technical Term

A solar module that captures light on both its front and rear surfaces, generating additional energy from reflected and diffuse light. Bifacial gains of 5–20% are possible depending on albedo, ground clearance, and mounting geometry.

BMS

Acronym

Battery Management System. The electronics and software that monitor and control individual cells and modules within a battery pack, ensuring safe operation within voltage, current, and temperature limits.

BMS Fault

Fault Code

Battery Management System fault indicating a cell-level or pack-level issue in a BESS — overvoltage, undervoltage, overcurrent, overtemperature, or cell imbalance. Requires review of BMS event logs before restart.

C

Capacity Test

Technical Term

A performance test that verifies a solar or storage system meets its contracted energy production or discharge capacity. Typically conducted over a defined period (e.g., 7-day or 30-day test) per the contract's test protocol.

CEC

Acronym

California Energy Commission. Issues the CEC-approved inverter and module lists referenced in many utility interconnection agreements and incentive programs. CEC efficiency ratings reflect real-world weighted performance.

Central Inverter

Technical Term

A large inverter (typically 100 kW to 4+ MW) that converts DC power from many combined strings to AC. Used in utility-scale and large commercial systems. Central inverters offer low cost per watt but create single points of failure.

Combiner Box

Technical Term

An enclosure that consolidates multiple PV strings into a single output, combining parallel strings with fuses, surge protection, and sometimes monitoring. String combiner boxes are used in central inverter systems to reduce wiring runs.

Communication Fault

Fault Code

Inverter cannot communicate with monitoring platform, energy meters, or other system components via RS485, Modbus, CAN bus, or Ethernet. Check wiring, termination resistors, and device addressing.

Cycle Life

Technical Term

The number of charge-discharge cycles a battery can complete before its capacity degrades to a specified end-of-life threshold (typically 70–80% of initial capacity). Lithium-ion BESS typically offers 4,000–10,000 cycles depending on chemistry and DoD.

D

DC

Acronym

Direct Current. The form of electricity produced by solar panels. Solar cells generate DC voltage that is aggregated through string wiring and converted to AC by the inverter.

DC/AC Ratio

Technical Term

Also called Inverter Loading Ratio (ILR). The ratio of a PV array's rated DC power to the inverter's rated AC output. Typical commercial ratios range from 1.1 to 1.3. Higher ratios increase clipping but improve low-light performance and inverter utilization.

Demand Charge Management

Technical Term

Strategies to reduce peak power demand, including battery discharge, load shifting, and inverter power limiting. Demand charges can represent 30–70% of a commercial electricity bill, making management highly valuable.

Depth of Discharge (DoD)

Technical Term

The percentage of battery capacity that has been discharged relative to total capacity. Higher DoD reduces cycle life. Most lithium-ion BESS systems are designed for 80–90% maximum DoD.

DSCR

Acronym

Debt Service Coverage Ratio. In solar project finance, the ratio of project cash flow to debt obligations. O&M support that reduces downtime directly improves DSCR and asset valuation.

E

Electroluminescence (EL) Testing

Technical Term

A diagnostic technique that applies current to a PV module in darkness and images the infrared light emitted by cells. EL imaging reveals microcracks, broken cells, PID, and other defects not visible to the naked eye.

EPC

Acronym

Engineering, Procurement, and Construction. An EPC contractor is responsible for the full delivery of a solar project — design, sourcing equipment, and building the system. EPCs are a primary customer segment for technical support services.

G

GFDI

Acronym

Ground Fault Detection and Interruption. A safety device or inverter function that detects ground faults in the PV array and disconnects power. Required by NEC 690.5 for grounded systems.

Ground Fault (GFDI)

Fault Code

A Ground Fault Detection and Interruption fault occurs when current flows from the PV array to ground unintentionally. In legacy SMA and SolarEdge systems, this appears as 'Isolation Failure' or 'Insulation Resistance Low'. Requires full array inspection before restart.

H

Half-Cut Cell

Technical Term

A module technology where standard cells are cut in half to reduce internal resistance and current. Half-cut modules have lower resistive losses, better shaded performance, and lower operating temperatures than full-cell modules.

I

I-V Curve

Acronym

Current-Voltage Curve. A graphical representation of the relationship between current and voltage in a solar module or string. I-V curve tracing is a key diagnostic tool for identifying shading, soiling, delamination, and cell degradation.

Inverter Clipping

Technical Term

Power loss that occurs when a PV array's DC output exceeds the inverter's maximum AC rating, causing the inverter to limit output. Common in oversized arrays (high DC/AC ratio). Visible as a flat-topped production curve on sunny days.

IOU

Acronym

Investor-Owned Utility. A privately owned electric utility that is subject to state regulation. IOUs have specific interconnection standards and processes for solar projects (e.g., PG&E, SCE, Duke Energy).

IPP

Acronym

Independent Power Producer. A company that generates electricity for sale to utilities or large customers but is not a public utility itself. IPPs frequently operate utility-scale solar and storage assets.

Isc

Acronym

Short-Circuit Current. The maximum current a solar module produces when its terminals are short-circuited. Used in string sizing calculations and as a reference point for I-V curve analysis.

Islanding Fault

Fault Code

The inverter detects that it is energizing a section of the grid that has been disconnected from the utility — a dangerous condition for line workers. Anti-islanding protection trips the inverter within 2 seconds per IEEE 1547.

Isolation Fault

Fault Code

Degraded insulation resistance between the PV array conductors and ground, below the inverter's minimum threshold (typically 1 MΩ for residential, higher for commercial). Common in wet or damaged wiring. Test with megohmmeter.

K

kWp

Acronym

Kilowatt-Peak. The rated power output of a solar installation under Standard Test Conditions (1000 W/m² irradiance, 25°C cell temperature). Used to size systems and report installed capacity.

M

Microinverter

Technical Term

A small inverter installed behind each individual module, converting DC to AC at the panel level. Eliminates string-level mismatch losses and enables per-module monitoring. Common brands: Enphase, APsystems, Hoymiles.

MPPT

Acronym

Maximum Power Point Tracking. An algorithm used by inverters and charge controllers to continuously find and maintain the optimal operating point on the I-V curve to extract maximum power from the solar array.

N

NEC

Acronym

National Electrical Code (NFPA 70). The benchmark for safe electrical installations in the United States. Article 690 specifically governs solar photovoltaic systems. Adopted by most jurisdictions with local amendments.

NEM

Acronym

Net Energy Metering. A utility billing arrangement where solar system owners receive credit for excess electricity exported to the grid. NEM policy varies by state and utility.

O

O&M

Acronym

Operations & Maintenance. The ongoing work to keep a solar asset producing at peak performance — including inspections, cleaning, fault response, inverter service, and monitoring. O&M companies are a major customer segment for remote technical support.

OCP

Acronym

Overcurrent Protection. Fuses and circuit breakers used in PV systems to protect wiring and equipment from damage due to excessive current. Required by NEC 690.9.

Overload Fault

Fault Code

Output current or power exceeds rated capacity. May indicate a load calculation error, short circuit downstream, or failed AC breaker. Inverter will derate or shut down to protect hardware.

Overtemperature (OTP)

Fault Code

Inverter internal temperature exceeds safe operating range. Causes include blocked ventilation, failed cooling fans, or high ambient temperatures. Inverter will derate or shut down. Check airflow clearances and fan operation.

Overvoltage (OVP)

Fault Code

Occurs when DC or AC voltage exceeds the inverter's rated input range. Common in cold climates where Voc increases. Inverters display 'Grid Overvoltage', 'PV Input Overvoltage', or 'MPPT OV'. Check Voc at STC vs. actual string configuration.

P

Peak Shaving

Technical Term

Using battery storage to discharge during periods of peak demand, reducing the maximum power drawn from the grid. Lowers demand charges for commercial customers. BESS size is determined by the load profile and billing structure.

PERC

Technical Term

Passivated Emitter and Rear Cell. A cell architecture that adds a passivation layer on the rear of the cell to reflect unabsorbed light back through the cell, improving efficiency. PERC has been the dominant cell technology in recent years.

Performance Ratio (PR)

Technical Term

A key metric comparing actual energy output to theoretical output under STC, adjusted for irradiance and temperature. PR accounts for all system losses (soiling, wiring, mismatch, inverter efficiency). A healthy system typically achieves PR of 75–85%.

PII

Acronym

Permit, Inspection, and Interconnection. The three administrative steps required to legally install and energize a solar system. Delays in PII can significantly extend project timelines.

PLC Error

Fault Code

Power Line Communication error — inverter cannot communicate with micro-inverters or optimizers over the AC wiring. Common in Enphase and SolarEdge systems. Check network connectivity, and filter interference from nearby switching equipment.

Pmax

Acronym

Maximum Power. The peak power output of a solar module at STC, typically the nameplate wattage. Measured in watts (W).

POI

Acronym

Point of Interconnection. The location where a solar or storage system connects to the utility grid — typically the revenue meter, switchgear, or substation.

Potential Induced Degradation (PID)

Technical Term

A performance loss caused by voltage-induced ion migration between solar cells and grounded module frames. PID can reduce output by 30%+ and is often reversible with inverter grounding configuration changes or PID recovery devices. Common in high-voltage strings.

Power Factor

Technical Term

The ratio of real power (watts) to apparent power (volt-amperes) in an AC circuit. Utilities often require solar systems to maintain a power factor between 0.95 leading and 0.95 lagging. Inverters can provide or absorb reactive power to meet these requirements.

Power Optimizer

Technical Term

A DC-DC converter attached to individual modules that performs MPPT at the panel level while still feeding a string inverter. Combines benefits of microinverters and string inverters. Primary brand: SolarEdge.

PPA

Acronym

Power Purchase Agreement. A contract in which a third-party developer installs, owns, and operates a solar system, and sells the electricity generated to the host customer at an agreed rate.

PV

Acronym

Photovoltaic. The technology that converts sunlight directly into electricity using semiconductor materials. Solar panels are composed of PV cells.

R

Rapid Shutdown

Technical Term

A NEC 690.12 requirement for PV systems on buildings to reduce energized conductor voltage to safe levels within 30 seconds of shutdown initiation. Requires module-level power electronics or controlled inverters.

Reactive Power

Technical Term

The portion of AC power that oscillates between source and load without performing useful work, measured in VARs. Inverters can generate or absorb reactive power for grid support. Utility-scale plants often have reactive power requirements in their interconnection agreements.

Round-Trip Efficiency

Technical Term

The ratio of energy discharged from a battery to the energy required to charge it, expressed as a percentage. Lithium-ion BESS typically achieves 85–95% round-trip efficiency. Lower efficiency means more energy lost as heat.

S

SCADA

Acronym

Supervisory Control and Data Acquisition. A control system used in utility-scale and large commercial solar plants to monitor, control, and collect data from inverters, meters, weather stations, and other devices.

Self-Consumption

Technical Term

The portion of solar energy generated that is used on-site rather than exported to the grid. Higher self-consumption improves solar economics under net billing or time-of-use rate structures. Battery storage increases self-consumption.

SLD

Acronym

Single-Line Diagram. An electrical schematic that uses single lines and standard symbols to represent a power system's components and their interconnections. Essential documentation for troubleshooting and commissioning.

Soiling Loss

Technical Term

Energy production reduction caused by dust, pollen, snow, bird droppings, or other debris accumulating on module surfaces. Soiling rates vary by region and season. Cleaning schedules should be based on soiling monitoring, not fixed intervals.

Startup Failure

Fault Code

Inverter fails to complete its self-check and grid synchronization sequence at startup. Can be caused by insufficient DC voltage, grid disturbances, or internal component failures. Review startup logs for specific sub-codes.

State of Charge (SoC)

Technical Term

The current energy level of a battery expressed as a percentage of its total capacity. BMS systems monitor SoC to prevent overcharge and over-discharge. Typical operating range is 10–90% SoC to extend battery life.

STC

Acronym

Standard Test Conditions. The benchmark conditions under which solar modules are rated: 1000 W/m² irradiance, 25°C cell temperature, AM 1.5 spectrum. Real-world performance often differs from STC ratings.

String Inverter

Technical Term

An inverter that converts DC power from a series-connected string of modules to AC. One string inverter typically serves multiple strings via multiple MPPT channels. Common in residential and small commercial systems.

T

Thermal Runaway

Technical Term

A dangerous condition in battery cells where heat generation exceeds heat dissipation, causing a self-sustaining temperature rise that can lead to fire or explosion. BMS systems are designed to prevent thermal runaway through cell-level monitoring and protection.

Thermography

Technical Term

The use of infrared imaging to detect temperature variations across a PV array. Hot spots, bypass diode failures, and degraded cells appear as thermal anomalies. Aerial thermography via drone is standard for large commercial and utility-scale inspections.

Time-of-Use (TOU)

Technical Term

A utility rate structure where electricity prices vary by time of day, with higher rates during peak demand periods. TOU rates affect the optimal sizing and operation of solar and storage systems.

TOPCon

Technical Term

Tunnel Oxide Passivated Contact. A next-generation cell technology that uses an ultra-thin tunnel oxide layer to reduce recombination losses. TOPCon cells achieve higher efficiency than PERC and are gaining market share.

U

Undervoltage (UVP)

Fault Code

AC or DC input voltage below operational threshold. Typically caused by shading, failed modules, string wiring faults, or utility disturbances. Displayed as 'Grid Undervoltage' or 'PV Start Voltage Not Reached'.

V

Vmp

Acronym

Voltage at Maximum Power. The voltage at which a solar module operates at its peak power output on the I-V curve. Used in string sizing to ensure modules operate within the inverter's MPPT range.

Voc

Acronym

Open-Circuit Voltage. The maximum voltage a solar module produces when no load is connected. Critical for string sizing — the combined Voc of a string must not exceed the inverter's maximum DC input voltage.